A report of the fifth quarter's work on the web-dendritic ribbon growth at the University of South Carolina is presented. A brief description of the work initiated and carried out during this period to meet the program goals is given along with a copy of the Program Plan covering the entire period of the contract. The web growth portion of this program was spent in the design, installation and testing of a new furnace geometry for the growth of dendritic web ribbon. The new installation was completed and the testing 90% accomplished. Results of the testing to determine the effect of the relative position of the r.f. coil with respect to the susceptor on the thermal profile in the melt are described. The one-dimensional thermal model has been used to determine the relationship between growth rate, web thickness, and mensicus height for stable growth. The results of this analysis are also given. An analysis was completed of the thermal radiation from the meniscus including the effect of the curvature of the meniscus with the results indicating that inclusion of the curvature leads to approximately a 10% increase in the radiation loss.

Research Organization:
South Carolina Univ., Columbia (USA). Coll. of Engineering
DOE Contract Number:
NAS-7-100-954344
OSTI ID:
7217217
Report Number(s):
ERDA/JPL/954344-76/4
Country of Publication:
United States
Language:
English