Title: Gamma scan measurements at Quad Cities Nuclear Power Station, Unit 1 following Cycle 2. Final report

Technical Report ·
OSTI ID:7213923

In July 1974, a project was begun to measure power distributions in operating reactors. The purpose of the project is to provide reference data for use in the qualification of reactor analysis computational methods. Detailed measurements have been performed at the Quad Cities No. 1 BWR, owned and operated by Commonwealth Edison Co. The results of measurements performed on fuel from this reactor at the end of Cycle 2 are presented.

Research Organization:
General Electric Co., San Jose, CA (USA). Nuclear Energy Systems Div.
OSTI ID:
7213923
Report Number(s):
PB-260626; TRN: 77-011766
Country of Publication:
United States
Language:
English