Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Improved ultrasonic nondestructive testing of pressure vessels. Annual progress report, August 1, 1975--July 31, 1976

Technical Report ·
OSTI ID:7211010

A synthetic aperture focusing technique for ultrasonic testing (SAFT UT) is described. The technique employs a single scanned transducer operating in pulse-echo mode with digital data acquisition and synthetic aperture post-processing to provide high lateral and longitudinal resolution. The extension of previously developed algorithms to provide volumetric processing and display is described. The design of a refreshed grey-scale display to provide interactive display of SAFT UT data is described.

Research Organization:
Michigan Univ., Ann Arbor (USA). Dept. of Mechanical Engineering
OSTI ID:
7211010
Report Number(s):
NUREG-0007-2
Country of Publication:
United States
Language:
English