Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Crude unit corrosion control: Underdeposit corrosion control for extended equipment life

Technical Report ·
OSTI ID:7207907
 [1]
  1. Petrolite Corp., St. Louis, MO (United States)
Failures of overhead equipment often occur at a much higher rate than probe measurements predict. This can be due to accelerated underdeposit pitting rates which are about twenty times the general rates. Underdeposit corrosion is primarily caused by iron sulfide deposits rather than neutralization salts as is commonly believed. The corrosion mechanism that leads to failures is the formation of a differential potential cell between the clean or lightly covered areas and the heavily deposited areas. Equations have been derived which show that the solubility of iron sulfide is dependent on pH and the concentration of sulfides present. These equations define the maximum pH at which a system can operate and remain free of iron sulfide deposits. Data are included which show that new generation inhibitors can control corrosion in the pH range necessary to prevent deposits. The goal of any program designed to minimize equipment failures should be to prevent the formation of deposits and the ensuring underdeposit pitting corrosion.
Research Organization:
Petrolite Corp., St. Louis, MO (United States)
OSTI ID:
7207907
Report Number(s):
AM-93-62
Country of Publication:
United States
Language:
English

Similar Records

New inhibitor reduces crude-unit corrosion problems at lower pH
Journal Article · Mon May 24 00:00:00 EDT 1993 · Oil and Gas Journal; (United States) · OSTI ID:6167271

Hydrogen sulfide corrosion can be controlled
Journal Article · Mon Nov 30 23:00:00 EST 1970 · Pet. Eng.; (United States) · OSTI ID:5854446

The role of biomineralization in microbiologically influenced corrosion
Conference · Wed Dec 30 23:00:00 EST 1998 · OSTI ID:350177