Partial discharge characteristics of oil-immersed insulation systems under dc, combined ac-dc and dc reversed polarity voltage

Conference · · IEEE Trans. Power Appar. Syst.; (United States)
OSTI ID:7194243
Breakdown characteristics of insulating oil, under combined ac-dc voltage and dc reversed polarity voltage, and partial discharge characteristics of oil-immersed insulation, under combined ac-dc voltage and polarity reversal of dc voltage were made clear by elementary experiments. After that, a numerical dc field mapping method for electric field analysis of two-dimensional configurations which consist of composite insulation and field mapping methods under combined ac-dc voltage and dc reversed polarity voltage were proposed. Furthermore, partial discharge characteristics of transformer insulation under dc, combined ac-dc voltage were experimentally made clear by practical trial models.