Intense lithium ion beam diagnostic using the inverse nuclear reactor D(/sup 7/Li,n)/sup 8/Be

Conference ·
OSTI ID:7190441
The decision to employ high voltage lithium ion beams on the 100 TW PBFA-II accelerator has prompted the investigation of using the inverse nuclear reaction D(/sup 7/Li,n)/sup 8/Be as an intense beam diagnostic. The diagnostic scheme operates by utilizing the high energy neutrons that are emitted from the D(/sup 7/Li,n)/sup 8/Be reaction when a /sup 7/Li beam is incident upon a target containing deuterons. These high energy neutrons can in turn induce the /sup 63/Cu(n,2n)/sup 62/Cu(..beta../sup +/) reaction. The amount of 9.74 min /sup 62/Cu activity formed can then be measured and related to the total number of /sup 7/Li in the beam. The results of calibration runs using /sup 7/Li beams accelerated to energies from 1 to 32 MeV are summarized.
Research Organization:
Sandia National Labs., Albuquerque, NM (USA); Iowa Univ., Iowa City (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
7190441
Report Number(s):
SAND-86-1382C; CONF-861114-38; ON: DE87004521
Country of Publication:
United States
Language:
English