Decoupling correction system in RHIC
Conference
·
· AIP Conference Proceedings (American Institute of Physics); (United States)
OSTI ID:7163209
- Brookhaven National Laboratory, Upton, New York 11973 (United States)
A global linear decoupling in the Relativistic Heavy Ion Collider (RHIC) is going to be performed with the three families of skew quadrupoles. The operating horizontal and vertical betatron tunes in the RHIC will be separated by one unit [nu][sub x]=28.19 and [nu][sub y]=29.18. The linear coupling is corrected by minimizing the tune splitting [Delta][nu]-the off diagonal matrix [bold m] (defined by Edwards and Teng). The skew quadrupole correction system is located close to each of the six interaction regions. A detail study of the system is presented by the use of the TEAPOT accelerator physics code. [copyright] 1994 American Institute of Physics
- OSTI ID:
- 7163209
- Report Number(s):
- CONF-931254--
- Conference Information:
- Journal Name: AIP Conference Proceedings (American Institute of Physics); (United States) Journal Volume: 315:1
- Country of Publication:
- United States
- Language:
- English
Similar Records
Decoupling correction system in RHIC
PRINCIPLE OF GLOBAL DECOUPLING WITH COUPLING ANGLE MODULATION.
A simulation study of linear coupling effects and their correction in RHIC
Conference
·
Thu Dec 30 23:00:00 EST 1993
·
OSTI ID:10134415
PRINCIPLE OF GLOBAL DECOUPLING WITH COUPLING ANGLE MODULATION.
Conference
·
Mon May 16 00:00:00 EDT 2005
·
OSTI ID:15016113
A simulation study of linear coupling effects and their correction in RHIC
Technical Report
·
Sat Oct 31 23:00:00 EST 1992
·
OSTI ID:6896985