Direct determination of part-per-billion levels of volatile organics in water and soil samples using glow discharge mass spectrometry
Conference
·
OSTI ID:7160558
A low pressure glow discharge ion source has been constructed in our laboratory and interfaced with a quadrupole mass spectrometer for the direct monitoring of trace organic vapors in air. Important features of this ion source include a simple design, low cost, low maintenance, and the ability to sample air directly without the need for membranes, splitters, or capillary restrictors. Although the flow rate of air into the source is approximately 2 standard mL per second, the pressure within the ionization region is maintained at 200 mTorr which reduces interferences caused by the formation of water cluster ions. Furthermore, the high flow rate of air into the ion source provides a simple and convenient means of purging volatile organics from water or soil samples directly into the mass spectrometer without additional apparatus or extensive sample preparation. Early studies with this system indicate that low part-per-billion levels of volatile organics such as benzene or tri-chloroethylene can be quantitatively determined in water and soil samples either by monitoring headspace above a sample or by direct purging. Analysis time of 2-5 minutes provides a high throughput of 10 or more samples per hour.
- Research Organization:
- Oak Ridge National Lab., TN (USA)
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 7160558
- Report Number(s):
- CONF-880768-1; ON: DE88011389
- Country of Publication:
- United States
- Language:
- English
Similar Records
Screening volatile organics by direct sampling ion trap and glow discharge mass spectrometry
Direct sampling ion trap mass spectrometry for the rapid determination of volatile organics in environmental matrices
Rapid characterization and monitoring by direct sampling ion trap mass spectrometry
Conference
·
Mon Dec 31 23:00:00 EST 1990
·
OSTI ID:6255594
Direct sampling ion trap mass spectrometry for the rapid determination of volatile organics in environmental matrices
Conference
·
Sat Dec 31 23:00:00 EST 1988
·
OSTI ID:5881902
Rapid characterization and monitoring by direct sampling ion trap mass spectrometry
Conference
·
Mon Jun 01 00:00:00 EDT 1992
·
OSTI ID:10149438
Related Subjects
37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CHEMISTRY
400102* -- Chemical & Spectral Procedures
CHEMICAL ANALYSIS
ELECTRIC DISCHARGES
GLOW DISCHARGES
HYDROGEN COMPOUNDS
MASS SPECTROSCOPY
MATTER
ORGANIC COMPOUNDS
OXYGEN COMPOUNDS
QUANTITATIVE CHEMICAL ANALYSIS
SOILS
SPECTROSCOPY
VOLATILE MATTER
WATER
400102* -- Chemical & Spectral Procedures
CHEMICAL ANALYSIS
ELECTRIC DISCHARGES
GLOW DISCHARGES
HYDROGEN COMPOUNDS
MASS SPECTROSCOPY
MATTER
ORGANIC COMPOUNDS
OXYGEN COMPOUNDS
QUANTITATIVE CHEMICAL ANALYSIS
SOILS
SPECTROSCOPY
VOLATILE MATTER
WATER