Effects of storage environment and nickel plating on the mechanical properties of U-0. 75 Ti
Technical Report
·
OSTI ID:7150821
The mechanical properties of bare and nickel plated U-0.75 Ti tensile bars were measured after exposures of up to 100 days to moist nitrogen atmospheres of 0-100% relative humidity. The relative humidity of the storage environment had no effect on the mechanical properties. Conversely, the nickel plating procedure significantly degraded mechanical properties. Sporadic low ductility values were also observed for bare U-0.75 Ti tensile bars.
- Research Organization:
- Sandia Labs., Albuquerque, NM (USA)
- OSTI ID:
- 7150821
- Report Number(s):
- SAND-80-8227
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effects of testing and storage environments on mechanical properties of Ni-plated and bare U-3/4 wt% Ti
Corrosion resistance of zinc-nickel plated U-O. 75 Ti
Effect of thin electrodeposited nickel coatings on the corrosion behavior of U-0. 75 Ti
Technical Report
·
Mon Dec 31 23:00:00 EST 1979
·
OSTI ID:5711638
Corrosion resistance of zinc-nickel plated U-O. 75 Ti
Technical Report
·
Sat Sep 01 00:00:00 EDT 1979
·
OSTI ID:5880244
Effect of thin electrodeposited nickel coatings on the corrosion behavior of U-0. 75 Ti
Journal Article
·
Tue Jun 01 00:00:00 EDT 1976
· Corrosion; (United States)
·
OSTI ID:7185568