Thermocline degradation in a packed-bed thermal storage tank
Journal Article
·
· J. Heat Transfer; (United States)
A time-dependent mathematical analysis of the fluid and solid temperature profiles of the bed during holding periods when no new fluid enters the tank was developed for the special case where the inlet fluid velocity is zero. The analysis incorporates the additional effects of thermal conduction and finite tank length.
- Research Organization:
- Sandia Lab.
- OSTI ID:
- 7142336
- Journal Information:
- J. Heat Transfer; (United States), Vol. 100:2
- Country of Publication:
- United States
- Language:
- English
Similar Records
Thermocline degradation in a packed bed thermal storage tank
Anharmonic analysis of a time-dependent packed bed thermocline
Thermal Ratcheting Analysis of TEDS Packed-bed Thermocline Energy Storage Tank - Modeling Methodology and Data Validation