skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Experimental research facility for creep-rupture testing of tantalum alloy T-111

Technical Report ·
OSTI ID:7140646

We have developed a research facility for computer-controlled elevated temperature tensile testing of refractory metallic alloys in an inert enviroment. In an application to tantalum alloy T-111, we have determined that a two-hour creep rupture life can be achieved at 1204/sup 0/C (0.45 T/sub m/) and 1300/sup 0/C (0.48 T/sub m/) if the applied true stresses are maintained below 46 ksi (317 MPa) and 36 ksi (248 MPa), respectively.

Research Organization:
Sandia National Labs., Livermore, CA (USA)
DOE Contract Number:
AC04-76DR00789
OSTI ID:
7140646
Report Number(s):
SAND-84-8221; ON: DE84012030
Country of Publication:
United States
Language:
English

Similar Records

Short term creep rupture predictions for tantalum alloy T-111
Conference · Tue Jan 01 00:00:00 EST 1991 · AIP Conference Proceedings (American Institute of Physics); (USA) · OSTI ID:7140646

Short term creep rupture predictions for Tantalum alloy T-3
Conference · Tue Jan 01 00:00:00 EST 1991 · OSTI ID:7140646

CORRELATION OF HIGH TEMPERATURE CREEP AND RUPTURE DATA
Journal Article · Tue Dec 01 00:00:00 EST 1959 · Journal of Basic Engineering (U.S.) Divided into J. Eng. Mater. Technol. and J. Fluids Eng. · OSTI ID:7140646