Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Removal of radioiodine from gas streams by electrolytic scrubbing

Journal Article · · Nucl. Technol.; (United States)
OSTI ID:7138640
Both molecular iodine and methyl iodide can be removed from air streams by electrolytic scrubbing using a solution of cobalt in dilute nitric acid. In a test system, 1350 ml/min of air containing 100 ppM CH/sub 3/I was contacted with 30 ml of 0.1M Co--8M HNO/sub 3/ in an anode compartment that had a current of 4A; this resulted in a decontamination factor (DF) of approximately 100 for iodine. A similar test using molecular iodine in air gave a DF of approximately 600.
Research Organization:
Oak Ridge National Lab., TN
OSTI ID:
7138640
Journal Information:
Nucl. Technol.; (United States), Journal Name: Nucl. Technol.; (United States) Vol. 30:3; ISSN NUTYB