Photon energy response of an aluminum oxide TLD environmental dosimeter

Conference ·
OSTI ID:7138005
Because of aluminum oxide's significant advantage in sensitivity (about a factor of 30) over LiF, minimal fading characteristics and ease of processing, aluminum oxide thermoluminescent dosimeters (TLDS) are being phased in at Los alamos for environmental monitoring of photon radiation. The new environmental dosimeter design consists of a polyethylene holder, about 0. 5 cm thick, loaded with a stack of four aluminum oxide TLD chips, each 1 mm thick and 5 mm in diameter. As part of the initial evaluation of the new design, the photon energy response of the dosimeter was calculated over the range from 10 keV to 1 MeV. Specific goals of the analysis included the determination of individual chip response in the stack, assessment of the response variation due to TLD material (i.e., LiF versus A1[sub 2] O[sub 3]), and the effect of copper filtration in flattening the response.
Research Organization:
Los Alamos National Lab., NM (United States)
Sponsoring Organization:
DOE; USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
7138005
Report Number(s):
LA-UR-92-3330; CONF-921005--7; ON: DE93003738
Country of Publication:
United States
Language:
English