Tritium storage development. Progress report No. 8, April--June 1976

Technical Report ·
DOI:https://doi.org/10.2172/7129684· OSTI ID:7129684

Lysimeter testing of polymer impregnated tritiated concrete (PITC) specimens at the Savannah River Laboratory (SRL) has continued. After twenty-three weeks, an average tritium fraction release rate of 3.37 x 10/sup -7/ day/sup -1/ has been determined in the percolate water with no measurable release to the air. Data from this experiment is extrapolated to estimate long-term tritium releases. A duplicate PITC specimen is in static leaching in distilled water. After seventy-two days, the average tritium fraction release rate has been 1.96 x 10/sup -5/ day/sup -1/. An estimation of the increased severity of static leaching in distilled water relative to lysimeter testing is made.

Research Organization:
Brookhaven National Lab., Upton, NY (USA)
DOE Contract Number:
EY-76-C-02-0016
OSTI ID:
7129684
Report Number(s):
BNL-50583
Country of Publication:
United States
Language:
English