Two-phase pump performance program preliminary test plan. Key phase report. [Water cooled reactor coolant loss transients]
Technical Report
·
OSTI ID:7125428
A preliminary test plan designed to provide basic data on the reactor coolant recirculation pump performance under two-phase flow LOCA conditions is described. The basic objectives of this program are to: (a) Obtain sufficient steady-state and transient two-phase empirical data to substantiate, and ultimately improve, the mathematical model of the reactor recirculation pump presently used for LOCA analysis; and (b) Obtain sufficient data on pump overspeed characteristics under transient two-phase blowdown conditions to verify the pump flywheel integrity to satisfy the requirements of the AEC Regulatory Guide No. 1.14. (GRA)
- Research Organization:
- C-E Power Systems, Windsor, CT (USA)
- OSTI ID:
- 7125428
- Report Number(s):
- PB-252750
- Country of Publication:
- United States
- Language:
- English
Similar Records
Two-phase pump performance program preliminary test plan. Key phase report. [PWR and BWR]
Pump behavior and its impact on a loss-of-coolant accident in a pressurized water reactor
Pump two-phase performance program. Volume 6. Transient data. Final report
Technical Report
·
Mon Sep 01 00:00:00 EDT 1975
·
OSTI ID:7300655
Pump behavior and its impact on a loss-of-coolant accident in a pressurized water reactor
Journal Article
·
Mon Jan 31 23:00:00 EST 1983
· Nucl. Technol.; (United States)
·
OSTI ID:5624263
Pump two-phase performance program. Volume 6. Transient data. Final report
Technical Report
·
Mon Sep 01 00:00:00 EDT 1980
·
OSTI ID:7042835