Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Validations with Critical Experiments Using Aqueous 235U in an Annular Tank

Conference · · Transactions of the American Nuclear Society
OSTI ID:7120517
Seventeen critical experiments employing an aqueous uranyl nitrate solution, 303 g U(93.0%)/l, in an annular tank were performed, with internal annular absorbers of polyethylene and/or stainless steel and/or an external annual reflector of carbon steel. Critical solution heights were determined by extrapolation of neutron multiplications as the height was increased. The o.d. of the solution annulus was 75 cm, and it was 8.92 cm thick. Modeling of the experiments with the Monte Carlo codes KENO-IV and MONK 6.2, and with the one-dimensional XSDRNPM transport code is reported here.
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP)
OSTI ID:
7120517
Report Number(s):
CONF-8711195-
Conference Information:
Journal Name: Transactions of the American Nuclear Society Journal Volume: 55
Country of Publication:
United States
Language:
English