Nickel/cadmium aircraft batteries: single sensor temperature monitoring. Technical note. [Detection of short circuits]

Technical Report ·
OSTI ID:7108303
Most of the failures of nickel/cadmium batteries in aircraft are triggered by the development of a short circuit in a single cell in the battery. An experiment was conducted to determine whether the use of a single temperature sensor on an intercell link would be adequate to warn of a short circuit in a cell located elsewhere in the battery. The results indicate that this would not be adequate.