Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

FFTF transient overpower accident: a perspective

Technical Report ·
DOI:https://doi.org/10.2172/709420· OSTI ID:709420
This paper is a reflection on the current understanding of the unprotected transient overpower (TOP) accident, in order to place it in perspective with regard to FFTF core energetics. The experimental data base is addressed, wtih particular emphasis on the E and H-series data, and its relevance to axial failure location and hydraulic fuel sweepout is considered. It is shown that the only way in which TOP could lead to a sizeable energy release is if either total plugging takes place or a plug at the radial center of the subassemblies propagates to the hex can walls prior to neutronics shutdown. (DLC)
Research Organization:
Hanford Engineering Development Lab., Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC06-76FF02170
OSTI ID:
709420
Report Number(s):
HEDL-TC--228
Country of Publication:
United States
Language:
English

Similar Records

FFTF transient overpower accident: a perspective
Conference · Tue Dec 31 23:00:00 EST 1974 · OSTI ID:4032237

Effect of intrasubassembly incoherencies on the fast test reactor unprotected transient overpower accident
Journal Article · Mon Dec 31 23:00:00 EST 1979 · Nucl. Technol.; (United States) · OSTI ID:5694319

Comparison of SAS3A and MELT-III predictions for a transient overpower hypothetical accident
Conference · Wed Dec 31 23:00:00 EST 1975 · OSTI ID:7334754