Detection of occult infection following total joint arthroplasty using sequential technetium-99m HDP bone scintigraphy and indium-111 WBC imaging

Journal Article · · J. Nucl. Med.; (United States)
OSTI ID:7074492

Preoperative exclusion or confirmation of periprosthetic infection is essential for correct surgical management of patients with suspected infected joint prostheses. The sensitivity and specificity of (/sup 111/In)WBC imaging in the diagnosis of infected total joint prostheses was examined in 28 patients and compared with sequential (/sup 99m/Tc)HDP/(/sup 111/In)WBC scintigraphy and aspiration arthrography. The sensitivity of preoperative aspiration cultures was 12%, with a specificity of 81% and an accuracy of 58%. The sensitivity of (/sup 111/In)WBC imaging alone was 100%, with a specificity of 50% and an accuracy of 65%. When correlated with the bone scintigraphy and read as sequential (/sup 99m/Tc)HDP/(/sup 111/In)WBC imaging, the sensitivity was 88%, specificity 95%, and accuracy 93%. This study demonstrates that (/sup 111/In)WBC imaging is an extremely sensitive imaging modality for the detection of occult infection of joint prostheses. It also demonstrates the necessity of correlating (/sup 111/In)WBC images with (/sup 99m/Tc)HDP skeletal scintigraphy in the detection of occult periprosthetic infection.

Research Organization:
Vanderbilt Univ., Nashville, TN (USA)
OSTI ID:
7074492
Journal Information:
J. Nucl. Med.; (United States), Journal Name: J. Nucl. Med.; (United States) Vol. 29:8; ISSN JNMEA
Country of Publication:
United States
Language:
English