Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Application of pulse combustion to incineration to liquid hazardous waste. Final report, September 1991-August 1993

Technical Report ·
OSTI ID:7073779
The report gives results of a study to determine the effect of acoustic pulsations on the steady-state operation of a pulse combuster burning liquid hazardous waste. A horizontal tunnel furnace was retrofitted with a liquid injection pulse combustor that burned No. 2 fuel oil. The fuel oil was doped with surrogate principal organic hazardous constituents (POHCs). For each test condition, the burner was operated in both a pulsing and nonpulsing mode. Large amplitude acoustic pulses were generated by adjusting the burner frequency to match the natural frequency of the combustion chamber. The combustion gases were sampled to quantify organic and particulate emissions. The results showed destruction and removal efficiency (DRE) values that were greater than six nines (99.9999%) for both pulsing and nonpulsing operations. The pulse combustor for the study was equipped with a fuel vaporization unit which may have enhanced the destruction capabilities of the burner.
Research Organization:
Environmental Protection Agency, Research Triangle Park, NC (United States). Air and Energy Engineering Research Lab.
OSTI ID:
7073779
Report Number(s):
PB-94-164415/XAB; EPA--600/R-94/060
Country of Publication:
United States
Language:
English