Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Solvent extraction studies with low-burnup Fast Flux Test Facility fuel in the Solvent Extraction Test Facility

Technical Report ·
DOI:https://doi.org/10.2172/707341· OSTI ID:707341

A batch of irradiated Fast Flux Test Facility (FFTF) fuel was processed for the first time in the Solvent Extraction Test Facility (SETF) at the Oak Ridge National Laboratory (ORNL) during Campaign 7. The average burnup of the fuel was only 0.2 atom %, but the cooling time was short enough ({similar_to}2 years) so that {sup 95}Zr was detected in the feed. This short cooling permitted our first measurement of {sup 95}Zr decontamination factors (DFs) without having to use tracers. No operational problems were noted in the operation of the extraction-scrubbing contactor, and low uranium and plutonium losses (< 0.01%) were measured. Fission product DFs were improved noticeably by increasing the number of scrub stages from six to eight. Two flowsheet options for making pure uranium and plutonium products (total partitioning) were tested. Each flowsheet used hydroxylamine nitrate for reducing plutonium. Good products were obtained (uranium DFs of > 10{sup 3} and plutonium DFs of > 10{sup 4}), but each flowsheet was troubled with plutonium reoxidation. Adding hydrazine and lowering the plutonium concentration lessened the problem but did not eliminate it. About 370 g of plutonium was recovered from these tests, purified by anion exchange, converted to PuO{sub 2}, and transferred to the fuel refabrication program. 7 references.

Research Organization:
Oak Ridge National Lab., TN (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-84OR21400
OSTI ID:
707341
Report Number(s):
ORNL/TM--9189; ON: TI85027064
Country of Publication:
United States
Language:
English