Ultra-clean underground counting facility for low-level environmental samples
Technical Report
·
OSTI ID:7073099
An underground counting facility has been designed and constructed to improve detection of low-level radionuclides. The 3.0 x 4.3 x 2.4 m counting chamber is placed 14.3 m below ground, has 10.2-cm thick walls of pre-WWII naval armor plate, and is further shielded by a minimum of 1.2 m of specular hematite. The total overburden of shielding is equivalent to 31.7 m of water. Careful selection of building materials and a special air filtering system maintain a cleanroom environment with minimum contamination potential. Background improvements are noted relative to an earlier ground-level counting chamber with 30.5-cm-thick walls of pre-WWII naval armor plate. Performance appraisals of facility detectors include a large dual NaI(Tl) coincidence system, three smaller NaI(Tl) detectors, and HPGe well detecotr, and gas proportional and Geiger counters. Major electronics for the detectors are located at a ground level control center to eliminate any associated backgrounds. Because an individual sample may be counted several days, uninterruptable power is used. An IBM PC/XT computer processes spectra from multi-channel analyzers using custom-developed software. 25 refs., 15 figs., 7 tabs.
- Research Organization:
- Savannah River Lab., Aiken, SC (USA)
- DOE Contract Number:
- AC09-76SR00001
- OSTI ID:
- 7073099
- Report Number(s):
- DP-1747; ON: DE88009235
- Country of Publication:
- United States
- Language:
- English
Similar Records
Ultra-clean underground counting facility for low-level environmental samples
Ultra-sensitive examination of environmental samples with SRL Underground Counting Facility
High sensitivity isotope analysis with a /sup 252/Cf--/sup 235/U fueled subcritical multiplier and low background photon detector systems
Conference
·
Tue Dec 31 23:00:00 EST 1985
·
OSTI ID:7025959
Ultra-sensitive examination of environmental samples with SRL Underground Counting Facility
Conference
·
Wed Dec 31 23:00:00 EST 1986
·
OSTI ID:6601210
High sensitivity isotope analysis with a /sup 252/Cf--/sup 235/U fueled subcritical multiplier and low background photon detector systems
Conference
·
Wed Sep 01 00:00:00 EDT 1976
·
OSTI ID:7257037
Related Subjects
42 ENGINEERING
420200 -- Engineering-- Facilities
Equipment
& Techniques
440300* -- Miscellaneous Instruments-- (-1989)
47 OTHER INSTRUMENTATION
AIR FILTERS
BACKGROUND RADIATION
BUILDING MATERIALS
CLEAN ROOMS
CONSTRUCTION
DATA ANALYSIS
DESIGN
ELEMENTS
EQUIPMENT
FILTERS
FLUIDS
GASES
GE SEMICONDUCTOR DETECTORS
GEIGER-MUELLER COUNTERS
HIGH-PURITY GE DETECTORS
ISOTOPES
MATERIALS
MEASURING INSTRUMENTS
MONITORING
NAI DETECTORS
NONMETALS
POLLUTION CONTROL EQUIPMENT
PROPORTIONAL COUNTERS
RADIATION DETECTORS
RADIATION MONITORING
RADIATIONS
RADIOISOTOPES
RADON
RARE GASES
SCINTILLATION COUNTERS
SEMICONDUCTOR DETECTORS
SHIELDING
SOLID SCINTILLATION DETECTORS
UNDERGROUND FACILITIES
420200 -- Engineering-- Facilities
Equipment
& Techniques
440300* -- Miscellaneous Instruments-- (-1989)
47 OTHER INSTRUMENTATION
AIR FILTERS
BACKGROUND RADIATION
BUILDING MATERIALS
CLEAN ROOMS
CONSTRUCTION
DATA ANALYSIS
DESIGN
ELEMENTS
EQUIPMENT
FILTERS
FLUIDS
GASES
GE SEMICONDUCTOR DETECTORS
GEIGER-MUELLER COUNTERS
HIGH-PURITY GE DETECTORS
ISOTOPES
MATERIALS
MEASURING INSTRUMENTS
MONITORING
NAI DETECTORS
NONMETALS
POLLUTION CONTROL EQUIPMENT
PROPORTIONAL COUNTERS
RADIATION DETECTORS
RADIATION MONITORING
RADIATIONS
RADIOISOTOPES
RADON
RARE GASES
SCINTILLATION COUNTERS
SEMICONDUCTOR DETECTORS
SHIELDING
SOLID SCINTILLATION DETECTORS
UNDERGROUND FACILITIES