CATCOM catalyst 5 atm 1000 hour aging study using No. 2 fuel oil

Conference ·
OSTI ID:7068635
The durability of the CATCOM catalyst for use in catalytically supported thermal combustion has been demonstrated at 5 atm, complementing a previous 1000 hour durability study at 1 atm. Both of these studies were conducted at about 640 K air preheat temperature at a reference velocity of about 14 m/s the adiabatic flame temperature of the fuel/air mixture was about 1530 K. The catalyst proved to be capable of low emissions operations after 1000 hours of diesel fuel aging. However, more severe deactivation occurred in the 5 atm test this was attributed to a loss in kinetic (ignition) activity.