Signal anomaly detection using modified CUSUM (cumulative sum) method
Conference
·
OSTI ID:7064891
An important aspect of detection of anomalies in signals is the identification of changes in signal behavior caused by noise, jumps, changes in band-width, sudden pulses and signal bias. A methodology is developed to identify, isolate and characterize these anomalies using a modification of the cumulative sum (CUSUM) approach. The new algorithm performs anomaly detection at three levels and is implemented on a general purpose computer. 7 refs., 4 figs.
- Research Organization:
- Tennessee Univ., Knoxville (USA). Dept. of Nuclear Engineering
- DOE Contract Number:
- AC02-86NE37959
- OSTI ID:
- 7064891
- Report Number(s):
- DOE/NE/37959-23; CONF-881208-2; ON: DE88008739
- Resource Relation:
- Conference: 27. IEEE conference on decision and control, Austin, TX, USA, 7 Dec 1988; Other Information: Portions of this document are illegible in microfiche products
- Country of Publication:
- United States
- Language:
- English
Similar Records
Signal anomaly detection and characterization
Detection of False Data Injection Attacks in Battery Stacks Using Input Noise-Aware Nonlinear State Estimation and Cumulative Sum Algorithms
Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations
Technical Report
·
Mon Aug 01 00:00:00 EDT 1988
·
OSTI ID:7064891
Detection of False Data Injection Attacks in Battery Stacks Using Input Noise-Aware Nonlinear State Estimation and Cumulative Sum Algorithms
Journal Article
·
Fri Aug 25 00:00:00 EDT 2023
· IEEE Transactions on Industry Applications
·
OSTI ID:7064891
Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations
Journal Article
·
Thu Oct 01 00:00:00 EDT 2020
· Energies
·
OSTI ID:7064891
+2 more
Related Subjects
22 GENERAL STUDIES OF NUCLEAR REACTORS
42 ENGINEERING
NUCLEAR POWER PLANTS
REACTOR MONITORING SYSTEMS
SIGNAL DISTORTION
DETECTION
C CODES
CLASSIFICATION
ELECTRICAL ENGINEERING
EQUATIONS
PULSE TECHNIQUES
REACTOR CONTROL SYSTEMS
REACTOR SAFETY
COMPUTER CODES
CONTROL SYSTEMS
ENGINEERING
NUCLEAR FACILITIES
POWER PLANTS
SAFETY
THERMAL POWER PLANTS
220400* - Nuclear Reactor Technology- Control Systems
420800 - Engineering- Electronic Circuits & Devices- (-1989)
42 ENGINEERING
NUCLEAR POWER PLANTS
REACTOR MONITORING SYSTEMS
SIGNAL DISTORTION
DETECTION
C CODES
CLASSIFICATION
ELECTRICAL ENGINEERING
EQUATIONS
PULSE TECHNIQUES
REACTOR CONTROL SYSTEMS
REACTOR SAFETY
COMPUTER CODES
CONTROL SYSTEMS
ENGINEERING
NUCLEAR FACILITIES
POWER PLANTS
SAFETY
THERMAL POWER PLANTS
220400* - Nuclear Reactor Technology- Control Systems
420800 - Engineering- Electronic Circuits & Devices- (-1989)