During the summer of 1991, nine negative cloud-to-ground lightning flashes, comprising a total of 38 individual return strokes, were triggered to designated attachment points on a munitions storage bunker. Measurements were simultaneously made of the incident flash currents, both return-stroke and continuing current components, and of response at 24 test points located throughout the bunker. The recorded responses included currents, voltages, and electric and magnetic fields throughout the structure and its lightning protection system. The maximum responses observed at each test point, as directly measured and a linearly scaled to median and severe return-stroke incident current amplitudes, are presented and discussed. 8 refs.