Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Personnel neutron dosimetry improvements at Los Alamos National Laboratory

Conference ·
OSTI ID:7044810
; ;  [1];  [2]
  1. Los Alamos National Lab., NM (United States)
  2. Texas A and M Univ., College Station, TX (United States). Dept. of Nuclear Engineering
We are investigating methods to improve neutron dosimetry at Los Alamos National Laboratory (LANL) using the track etch dosemeter CR-39. Specifically, use of CR-39 for dynamic environments, typically encountered at the LANL Plutonium Facility, is shown to be a superior method for personnel neutron dosimetry when compared to the currently used TLD system. The results of glovebox experiments simulating hydrogenous shielding used at LANL, temporal variations of neutron correction factors used at the Plutonium Facility, trial implementation at this facility and preliminary neutron spectroscopy measurements are presented and compared to reference dosimetry measurements. Our results confirm that use of a TLD system in a facility implementing hydrogenous shielding requires frequent field re-calibration. When such correction factors are not re-evaluated frequently, or are maintained at pre-shielding levels, significant (i.e., 2- to 3-fold) overestimation of the neutron dose equivalent can occur.
Research Organization:
Los Alamos National Lab., NM (United States)
Sponsoring Organization:
DOE; USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
7044810
Report Number(s):
LA-UR-92-2243; CONF-920702--2; ON: DE92018374
Country of Publication:
United States
Language:
English