The NRC staff evaluation of shutdown and low-power operation at nuclear power plants in the United States
- Nuclear Regulatory Commission, Washington, DC (United States)
The results of the US Nuclear Regulatory Commission (NRC) staff's recent evaluation of shutdown and low-power operations at US commercial nuclear power plants are summarized in this paper. The NRC staff's evaluation was initiated following their investigation of the loss during shutdown of all vital alternating current power on March 20, 1990, at the Alvin W. Vogtle nuclear plant. The objective of the evaluation has been to assess risk broadly during shutdown, refueling, and startup, addressing not only issues raised by the Vogtle event, but also a number of other shutdown-related issues that had been identified by foreign regulatory organizations as well as the NRC and any new issues uncovered in the evaluation process. The key issues concerning shutdown risk identified in the integration process described earlier and subsequently addressed by the staff include the following: (1) outage planning and control; (2) stress on personnel and programs; (3) the need to improve training and procedures; (4) technical specifications; and (5) PWR safety during midloop operation. Other technical topics identified for further study by the staff included loss of RHR, containment capability, rapid boron dilution, fire protection, instrumentation, emergency core cooling system recirculation capability, effect of PWR upper internals, on-site emergency planning, fuel handling and heavy loads, potential for draining the BWR reactor vessel, reporting requirements for shutdown events, and need to strengthen inspection program.
- OSTI ID:
- 7044187
- Report Number(s):
- CONF-920606-; CODEN: TANSA
- Journal Information:
- Transactions of the American Nuclear Society; (United States), Vol. 65; Conference: American Nuclear Society annual meeting, Boston, MA (United States), 7-12 Jun 1992; ISSN 0003-018X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Preliminary results of the PWR low power and shutdown accident frequencies program: Coarse screening analysis for Surry
Risk contribution from low power, shutdown, and other operational modes beyond full power
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
BWR TYPE REACTORS
REACTOR SAFETY
REACTOR SHUTDOWN
PWR TYPE REACTORS
BORON
ENGINEERED SAFETY SYSTEMS
HEAT TRANSFER
HYDRAULICS
PROBABILISTIC ESTIMATION
REACTOR FUELING
REACTOR OPERATION
REACTOR START-UP
REGULATIONS
RHR SYSTEMS
RISK ASSESSMENT
SAFETY INJECTION
US NRC
VOGTLE-1 REACTOR
COOLING SYSTEMS
ELEMENTS
ENERGY TRANSFER
ENRICHED URANIUM REACTORS
FLUID MECHANICS
MECHANICS
NATIONAL ORGANIZATIONS
OPERATION
POWER REACTORS
REACTOR COMPONENTS
REACTOR COOLING SYSTEMS
REACTORS
SAFETY
SEMIMETALS
SHUTDOWN
START-UP
THERMAL REACTORS
US ORGANIZATIONS
WATER COOLED REACTORS
WATER MODERATED REACTORS
220900* - Nuclear Reactor Technology- Reactor Safety
210100 - Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled
210200 - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled