Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Time-domain calculation of the leakage of SGEMP transients through braided cable shields

Conference · · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA)
OSTI ID:7038101

This paper presents a time-domain technique for calculating the leakage of SGEMP transients through braided cable shields. Detailed numerical results are given which illustrate the effects of spatial and temporal variations in shield current and voltage on the transient which penetrates the inner conductor of a braided shield cable.

OSTI ID:
7038101
Report Number(s):
CONF-890723--
Journal Information:
IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA), Journal Name: IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) Vol. 36:6; ISSN 0018-9499; ISSN IETNA
Country of Publication:
United States
Language:
English

Similar Records

A FEM approach to shielding effectiveness in braided-shield cables
Journal Article · Wed Feb 28 23:00:00 EST 1990 · IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (USA) · OSTI ID:6527308

Shielding effectiveness of multiple-shield cables with arbitrary terminations via transmission line analysis
Journal Article · Sat Jun 25 00:00:00 EDT 2016 · Progress in Electromagnetics Research C · OSTI ID:1340178

SGEMP-induced transfer admittance coupling in cable bundles
Journal Article · Tue Nov 30 23:00:00 EST 1982 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:5922410