Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Graphic display development methodology: Volume 1, Theory: Final report

Technical Report ·
OSTI ID:7037595
The Graphic Display Development Program is intended to develop computer-based displays which support the symptomatic emergency operating procedures for BWRs. The purpose is to provide a technical basis and methodology for linking two post-TMI safety initiatives: improved operating procedures and the Safety Parameter Display System (NUREG-0737 Supplement 1). Whereas consistency between displays and emergency operating procedures is desirable, no assumption of such an NRC requirement is either expressed or implied in this document. Accordingly, this program should be viewed not as the only acceptable approach to SPDS design but as one of many possible approaches which may be pursued. This program has been supported as a generic activity on behalf of the Boiling Water Reactor Owner's Group (BWROG). No endorsement by any individual utility member of the BWROG is either expressed or implied in this document, nor is any utility obligated to implement this program at any plant.
Research Organization:
Operations Engineering, Inc., Fremont, CA (USA)
OSTI ID:
7037595
Report Number(s):
EPRI-NP-4874-Vol.1; ON: DE87003332
Country of Publication:
United States
Language:
English