Title: Single-gap multi-harmonic buncher for NSC pelletron

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.58948· OSTI ID:703526
; ; ; ; ; ; ; ; ; ; ; ; ; ;  [1];  [2]
  1. Nuclear Science Center, Aruna Asaf Ali Marg, Post Box-10502, New Delhi-110067 (India)
  2. Physics Division, Argonne National Laboratory, Argonne, 9700 South Cass Avenue, Illinois-60439 (United States)

A single-gap multi-harmonic buncher, developed in collaboration with Argonne National Laboratory, has been installed in the pre-acceleration region of NSC Pelletron. This buncher is required for injecting bunched beam into the booster LINAC, presently under construction. A saw-tooth voltage generated across a single gap formed by a closely spaced pair of grids is used for bunching the dc ion beam produced by the Pelletron accelerator. This saw-tooth voltage is produced by adding a sinewave with its three higher harmonics in proper phase and amplitude. {sup 28}Si beam has been bunched successfully using this buncher. The best FWHM of the bunched beam was 1.5ns and the maximum efficiency of bunching was 50{percent}. The bunching voltage had no steering effect on the beam. {copyright} {ital 1999 American Institute of Physics.}

Sponsoring Organization:
USDOE
OSTI ID:
703526
Report Number(s):
CONF-981087-; ISSN 0094-243X; TRN: 9918M0034
Journal Information:
AIP Conference Proceedings, Vol. 473, Issue 1; Conference: 8. international conference on heavy ion accelerator technology, Argonne, IL (United States), 5-10 Oct 1998; Other Information: PBD: Apr 1999
Country of Publication:
United States
Language:
English

Similar Records

Single-gap multi-harmonic buncher for NSC pelletron
Journal Article · Mon Apr 26 00:00:00 EDT 1999 · AIP Conference Proceedings · OSTI ID:703526

Four-harmonic buncher for radioactive and stable beams switching at the ATLAS facility [Four-harmonic buncher for radioactive and stable beams combination at the ATLAS facility]
Journal Article · Mon Jul 23 00:00:00 EDT 2018 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:703526

Four-harmonic buncher for effective combination of radioactive and stable beams
Technical Report · Thu Jul 19 00:00:00 EDT 2018 · OSTI ID:703526