skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Second coordinate readout in drift chambers by timing of the electromagnetic wave propagating along the anode wire

Conference ·
OSTI ID:7034012

The feasibility of using an anode wire and surrounding electrodes in drift chambers as a transmission line for second coordinate readout has been studied. The method is based on propagation of the electromagnetic wave along the anode wire is determined by measurement, in an optimized electronic readout system, of the time difference between the arrivals of the signal to the ends of the wire. The resolution obtained on long wires (approx. 2 meters) is about 2 cm FWHM for minimum ionizing particles at a gas gain of approx. = 10/sup 5/.

Research Organization:
Brookhaven National Lab., Upton, NY (USA)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
7034012
Report Number(s):
BNL-28660; CONF-801103-27; TRN: 81-001147
Resource Relation:
Conference: IEEE nuclear science symposium, Orlando, FL, USA, 5 Nov 1980
Country of Publication:
United States
Language:
English