Selection of dimensions of scintillation detectors and of the correction energy with the use of the dual energy method in computerized tomography
Journal Article
·
· Sov. J. Nondestr. Test. (Engl. Transl.); (United States)
OSTI ID:7026956
The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. The results of numerical calculations for actual materials and of the registration by count are presented.
- Research Organization:
- Research Institute of Electronic Introscopy, Tomsk
- OSTI ID:
- 7026956
- Journal Information:
- Sov. J. Nondestr. Test. (Engl. Transl.); (United States), Vol. 21:9
- Country of Publication:
- United States
- Language:
- English
Similar Records
Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography
Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions
A radiation detection system for high-energy computerized tomography using CdZnTe detectors
Journal Article
·
Sun Mar 15 00:00:00 EDT 2015
· Medical Physics
·
OSTI ID:7026956
Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions
Journal Article
·
Mon Oct 14 00:00:00 EDT 2013
· Journal of Applied Physics
·
OSTI ID:7026956
A radiation detection system for high-energy computerized tomography using CdZnTe detectors
Journal Article
·
Tue Aug 01 00:00:00 EDT 1995
· IEEE Transactions on Nuclear Science
·
OSTI ID:7026956
+5 more
Related Subjects
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
SOLID SCINTILLATION DETECTORS
CALIBRATION
SIZING
CORRECTIONS
CRYSTALS
OPTIMIZATION
PHOTON COMPUTED TOMOGRAPHY
SCINTILLATION COUNTING
COMPUTERIZED TOMOGRAPHY
COUNTING TECHNIQUES
DIAGNOSTIC TECHNIQUES
MEASURING INSTRUMENTS
RADIATION DETECTORS
SCINTILLATION COUNTERS
TOMOGRAPHY
440101* - Radiation Instrumentation- General Detectors or Monitors & Radiometric Instruments
SOLID SCINTILLATION DETECTORS
CALIBRATION
SIZING
CORRECTIONS
CRYSTALS
OPTIMIZATION
PHOTON COMPUTED TOMOGRAPHY
SCINTILLATION COUNTING
COMPUTERIZED TOMOGRAPHY
COUNTING TECHNIQUES
DIAGNOSTIC TECHNIQUES
MEASURING INSTRUMENTS
RADIATION DETECTORS
SCINTILLATION COUNTERS
TOMOGRAPHY
440101* - Radiation Instrumentation- General Detectors or Monitors & Radiometric Instruments