A laboratory and field test were performed to select and evaluate possible replacement sorbents for sampling volatile organic compounds in stationary sources using SW-846 Method 0030. On the basis of laboratory results, Anasorb 747 was selected for testing in the field using dynamic spiking procedures. This modification of the VOST method uses a single tube containing Anasorb 747 that is preceded by two tubes containing Tenax. The modified VOST method was compared in the field with the VOST method using traditional adsorbents. Both the VOST and modified VOST used a quadruple probe and four similar sampling trains, using the same certified compressed gas cylinder as a source of test compounds. As a general observation, the recovery and precision of most compounds is improved by using the modified VOST procedure.

Research Organization:
Radian Corp., Research Triangle Park, NC (United States)
OSTI ID:
7017893
Report Number(s):
PB-94-176633/XAB; CNN: EPA-68-D1-0010
Resource Relation:
Other Information: See also PB--84-234525, PB--91-145979, PB--93-212181, PB--93-227163 and PB--93-227171
Country of Publication:
United States
Language:
English