Standard test method for mist spray flammability of hydraulic fluids
Journal Article
·
· Annu. Book ASTM Stand.; (United States)
OSTI ID:7014939
A method for the determination of one aspect of the flammability of hydraulic fluids and that is particularly useful for rating the relative flammability of mists of fire resistant hydraulic fluids is described. The fluid is preheated, and then placed in a rotary-type electric paint spray gun, and sprayed into the flame of a laboratory burner. The flammability is then rated by the operator on a relative scale. Fluids to be compared shall be tested by the same operator on a single day using the same apparatus.
- OSTI ID:
- 7014939
- Journal Information:
- Annu. Book ASTM Stand.; (United States), Journal Name: Annu. Book ASTM Stand.; (United States) Vol. 25; ISSN ASTSA
- Country of Publication:
- United States
- Language:
- English