skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Assessment of TRAC-PF1/MOD1 Version 14. 3 using separate effects critical flow and blowdown experiments

Technical Report ·
OSTI ID:7013117
;  [1]
  1. CEA Centre d'Etudes Nucleaires de Grenoble, 38 (France)

Independent assessment of the TRAC code was conducted at the Centre d'Etudes Nucleaires de Grenoble of the Commissariate a l'Energie Atomique (France) in the frame of the ICAP. This report presents the results of the assessment of TRAC-PF1/MOD1 version 14.3 using critical flow steady state tests (MOBY-DICK, SUPER-MOBY-DICK), and blowdown tests (CANON, SUPER-CANON, VERTICAL-CANON, MARVIKEN, OMEGA-TUBE, OMEGA-BUNDLE). This document, Volume 2, presents the experimental data and figures from the assessment.

Research Organization:
Nuclear Regulatory Commission, Washington, DC (USA). Office of Nuclear Regulatory Research; CEA Centre d'Etudes Nucleaires de Grenoble, 38 (France)
Sponsoring Organization:
USNRC
OSTI ID:
7013117
Report Number(s):
NUREG/IA-0023-Vol.2; ON: TI90010755; TRN: 90-016228
Country of Publication:
United States
Language:
English