Boiler tube failures: Case histories of steam blanketing and underdeposit corrosion

Conference ·
OSTI ID:70127
 [1]
  1. Betz Labs., The Woodlands, TX (United States)
Case histories in which boiler tube failures resulted from a combination of steam blanketing and underdeposit corrosion are reviewed. Steam blanketing originates from inadequate circulation and commonly occurs in horizontal or sloped boiler tube circuits in the root of a boiler. It can lead to boiler tube corrosion failures by providing a mechanism for concentration of normally soluble species at or above a liquid/vapor interface.
OSTI ID:
70127
Report Number(s):
CONF-940222--
Country of Publication:
United States
Language:
English

Similar Records

Boiler tube failures: Case histories of steam blanketing and underdeposit corrosion
Journal Article · Mon Aug 01 00:00:00 EDT 1994 · Materials Performance; (United States) · OSTI ID:7228705

Phosphate attack as caustic corrosion in high-pressure boiler tubes
Journal Article · Sun Feb 28 23:00:00 EST 1999 · Materials Performance · OSTI ID:6441086

Some common corrosion mechanisms leading to boiler tube failure