Development of an expert system for signal validation: Topical report
Technical Report
·
OSTI ID:7010984
A signal validation and sensor information expert system is developed and applied to nuclear power plant subsystems. The expert system interactively provides the user with a list of sensors used to monitor a subsystem of a power plant and answers the user's questions about the characteristics of those sensors. The expert system performs an evaluation of the present output characteristics of an instrument channel. The evaluation is fully automated and is designed to mimic an operator's approach to signal validation. The evaluation is designed to detect three types of possible sensor anomalies: (1) incorrect average output, (2) improper noise level,and (3) incorrect response to a system perturbation. There are two tests used to detect each possible anomalous condition. One test is a comparison of the specified sensor characteristic against the same characteristic of its redundant sensors. The second test is a prediction of the sensor's expected behavior and comparison with its observed behavior. The evaluation was tested using operational data from twelve sensors used to monitor level, pressure, primary and secondary coolant flow rates, and hot and cold leg temperatures of a steam generator in a commercial nuclear power plant. The results of the testing demonstrated successfully that the evaluation detected the three possible anomalies, and was able to handle conflicting information using the comparison among redundant sensors and the system specific test used to detect the anomalies.
- Research Organization:
- Tennessee Univ., Knoxville (USA). Dept. of Nuclear Engineering
- DOE Contract Number:
- AC02-86NE37959
- OSTI ID:
- 7010984
- Report Number(s):
- DOE/NE/37959-17; ON: DE88013077
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of an expert system for signal validation
Development of an expert system for signal validation
Generalized consistency checking of multivariable redundant measurements (GCCM) and common-mode failure detection
Conference
·
Wed Jun 01 00:00:00 EDT 1988
·
OSTI ID:6711289
Development of an expert system for signal validation
Conference
·
Thu Dec 31 23:00:00 EST 1987
· Transactions of the American Nuclear Society; (USA)
·
OSTI ID:5580660
Generalized consistency checking of multivariable redundant measurements (GCCM) and common-mode failure detection
Technical Report
·
Sat Dec 31 23:00:00 EST 1988
·
OSTI ID:6457472
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
210200 -- Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
22 GENERAL STUDIES OF NUCLEAR REACTORS
220400* -- Nuclear Reactor Technology-- Control Systems
99 GENERAL AND MISCELLANEOUS
990210 -- Supercomputers-- (1987-1989)
BOILERS
DATA ACQUISITION
EXPERT SYSTEMS
KNOWLEDGE BASE
LISP
NUCLEAR FACILITIES
NUCLEAR POWER PLANTS
POWER PLANTS
PROGRAMMING LANGUAGES
PWR TYPE REACTORS
REACTOR INSTRUMENTATION
REACTORS
REMOTE SENSING
SIGNALS
STEAM GENERATORS
TESTING
THERMAL POWER PLANTS
VALIDATION
VAPOR GENERATORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200 -- Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
22 GENERAL STUDIES OF NUCLEAR REACTORS
220400* -- Nuclear Reactor Technology-- Control Systems
99 GENERAL AND MISCELLANEOUS
990210 -- Supercomputers-- (1987-1989)
BOILERS
DATA ACQUISITION
EXPERT SYSTEMS
KNOWLEDGE BASE
LISP
NUCLEAR FACILITIES
NUCLEAR POWER PLANTS
POWER PLANTS
PROGRAMMING LANGUAGES
PWR TYPE REACTORS
REACTOR INSTRUMENTATION
REACTORS
REMOTE SENSING
SIGNALS
STEAM GENERATORS
TESTING
THERMAL POWER PLANTS
VALIDATION
VAPOR GENERATORS
WATER COOLED REACTORS
WATER MODERATED REACTORS