Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Gallium arsenide integrated optical devices in adverse environments

Conference ·
OSTI ID:7005354
We discuss preliminary measurements of the response of gallium arsenide integrated optical-waveguides to radiation from a Febetron. The Febetron produces electrons in the 300-700 keV range in approximately 3-ns FWHM pulses, with a maximum dose rate of approximately 10/sup 14/ rad/sec. ''Prompt'' radiation effects were monitored on a streak camera recording system. 7 refs., 6 figs.
Research Organization:
Lawrence Livermore National Lab., CA (USA)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
7005354
Report Number(s):
UCRL-97806; CONF-871161-2; ON: DE88014485
Country of Publication:
United States
Language:
English