Low jitter Marx generator for cold-cathode E-beam sources

Journal Article · · Chin. Phys. Lasers; (United States)
OSTI ID:6993799

The delay and jitter characteristics of the three-electrode spark-gap were studied. A three-stage Marx generator was designed using synchronous trigger pulses for each spark gap. Risetime of the output voltage of the Marx generator can be controlled to within less than 100 ns, with the jitter time in the range of 5--10 ns.

Research Organization:
Shanghai Institute of Optics and Fine Mechanics, Academia Sinica
OSTI ID:
6993799
Journal Information:
Chin. Phys. Lasers; (United States), Journal Name: Chin. Phys. Lasers; (United States) Vol. 13:7; ISSN CPLAE
Country of Publication:
United States
Language:
English