Title: Modifications and assessment of rewetting correlations for light water reactor system analysis

Conference · · Trans. Am. Nucl. Soc.; (United States)
OSTI ID:6992940

The qualitative aspects of reflood heat transfer in the system codes (e.g., RELAP5/MOD2, TRAC-PF1/MOD1, COBRA-TF, etc.) can be represented with a generalized boiling curve. The anchor points used to specify the boiling curve are the critical heat flux (CHF) temperature (T/sub CHF/) and the minimum flow boiling temperature (T/sub min/). The cooldown during the quenching process is affected by the minimum film boiling heat flux. This aspect of the quenching process has not been studied as much as the CHF phenomenon. The purpose of this paper is to compare several rewetting correlations. These correlations were implemented in a special version of RELAP5/MOD2 computer code. Good comparison between several FLECHT-SEASET data and predicted rewetting temperatures was obtained when a new modified formulation of Henry rewetting correlation was used to account for the mass rate dependence.

Research Organization:
Texas A and M, College Station
OSTI ID:
6992940
Report Number(s):
CONF-861102-; TRN: 87-008126
Journal Information:
Trans. Am. Nucl. Soc.; (United States), Vol. 53; Conference: American Nuclear Society and Atomic Industrial Forum joint meeting, Washington, DC, USA, 16 Nov 1986
Country of Publication:
United States
Language:
English