Effects of field orientation during 700-MHz radiofrequency irradiation of rats
Journal Article
·
· Physiological Chemistry and Physics and Medical NMR; (USA)
OSTI ID:6991410
- School of Aerospace Medicine, Brooks AFB, TX (USA)
Ketamine-anesthetized Sprague-Dawley rats were exposed to far-field 700-MHz continuous-wave radiofrequency radiation (RFR) in both E and H orientations. Irradiation was conducted at whole-body average specific absorption rates (SARs) of 9.2 and 13.0 W/kg (E and H, respectively) that resulted in approximately equivalent colonic specific heating rates (SHRs). Exposures were performed to repeatedly increase colonic temperature by 1 degree C (38.5 to 39.5 degrees C). Tympanic, tail, left and right subcutaneous (toward and away from RFR source), and colonic temperatures, arterial blood pressure, and respiratory rate were continuously recorded. In spite of equivalent colonic SHRs and the reduced E-orientation average SAR, the right subcutaneous, tympanic, and tail SARs, SHRs and absolute temperature increases were significantly greater in E than in H orientation. The cooling rate at all monitoring sites was also significantly greater in E than in H orientation. Heart rate and mean arterial blood pressure significantly increased during irradiation; however, changes between orientations were not different. Respiratory rate significantly increased during irradiation in H, but not in E orientation. These results indicate that during resonant frequency irradiation, differences occur in the pattern of heat deposition between E- and H-orientation exposure. When compared with previous investigations performed at supraresonant frequencies, the lower level of cardiovascular change in this study was probably related to the lower periphery-to-core thermal gradient.
- OSTI ID:
- 6991410
- Journal Information:
- Physiological Chemistry and Physics and Medical NMR; (USA), Journal Name: Physiological Chemistry and Physics and Medical NMR; (USA) Vol. 21:1; ISSN PCPNE; ISSN 0748-6642
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effects of field orientation during 700-MHz radiofrequency irradiation of rats
Field orientation effects during 5. 6-GHz radiofrequency irradiation of rats
Thermoregulatory responses of rats exposed to 9. 3-GHz radio-frequency radiation
Technical Report
·
Sat Dec 31 23:00:00 EST 1988
·
OSTI ID:7189000
Field orientation effects during 5. 6-GHz radiofrequency irradiation of rats
Journal Article
·
Fri Nov 30 23:00:00 EST 1990
· Aviation, Space and Environmental Medicine; (USA)
·
OSTI ID:6003833
Thermoregulatory responses of rats exposed to 9. 3-GHz radio-frequency radiation
Technical Report
·
Thu Oct 15 00:00:00 EDT 1987
·
OSTI ID:6831499
Related Subjects
560400* -- Other Environmental Pollutant Effects
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
ANIMALS
BIOLOGICAL EFFECTS
BLOOD PRESSURE
BODY TEMPERATURE
CARDIOVASCULAR SYSTEM
ELECTROMAGNETIC RADIATION
FREQUENCY RANGE
MAMMALS
MHZ RANGE
MHZ RANGE 100-1000
RADIATIONS
RADIOWAVE RADIATION
RATS
RESPIRATION
RODENTS
VERTEBRATES
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
ANIMALS
BIOLOGICAL EFFECTS
BLOOD PRESSURE
BODY TEMPERATURE
CARDIOVASCULAR SYSTEM
ELECTROMAGNETIC RADIATION
FREQUENCY RANGE
MAMMALS
MHZ RANGE
MHZ RANGE 100-1000
RADIATIONS
RADIOWAVE RADIATION
RATS
RESPIRATION
RODENTS
VERTEBRATES