Small gas turbines exhibit single-digit emissions in service

Journal Article · · Diesel and Gas Turbine Worldwide; (United States)
OSTI ID:6983822

A 10 MW-class, THM 1304-10D gas turbine from MAN-GHH, equipped with dry low-NO[sub x] combustion chambers, including hybrid burners, entered service last October. The unit was installed on the Stegal long-distance natural gas pipeline from the Olbernhau compression station on the Czech border. The pipeline transmits gas from Russia to the central part of Germany. A similar compression station, featuring three THM 1304-D driven compressor packages, started commercial operation last March in the Rehden station on the Midal pipeline. A test program carried out by MAN-GHH has demonstrated that the THM 1304 gas turbine has a wide operating range with NO[sub x] emission well under TA luft limits and, at the same time, negligible CO emissions. This is accomplished by combined effect of large volume combustion chambers, optimized wall cooling and premix dry low-NO[sub x] burners. 3 figs.

OSTI ID:
6983822
Journal Information:
Diesel and Gas Turbine Worldwide; (United States), Journal Name: Diesel and Gas Turbine Worldwide; (United States) Vol. 26:5; ISSN DGWODS; ISSN 0278-5994
Country of Publication:
United States
Language:
English