Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Materials, Processes, and Testing Laboratory. Technical progress report, March-June 1981

Technical Report ·
DOI:https://doi.org/10.2172/6971726· OSTI ID:6971726
Test experience with photovoltaic (PV) modules at various experimental test facilities are detailed. Specific details are presented for site visits where electrically failed modules were found and replaced at Mead, Nebraska and Bryan, Ohio. Broken interconnects at all sites were reported and analyzed. A search for electrically failed modules at the Systems Test Facility (STF) array field was reported and analyzed. Several photovoltaic/thermal (PV/T) modules were analyzed for specific defects. (LEW)
Research Organization:
Massachusetts Inst. of Tech., Lexington (USA). Lincoln Lab.
DOE Contract Number:
AC02-76ET20279
OSTI ID:
6971726
Report Number(s):
DOE/ET/20279-152; ON: DE83000062
Country of Publication:
United States
Language:
English