skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Extension of Fong and Alvarez: When is a lower limit of detection low enough?

Journal Article · · Health Physics

The work of Fong and Alvarez is easily extended for counting when varied counting is not employed. It remains true in the general case that the precision of a counting method can be no less than about 30% at the LLD and so it is desirable to have decision levels at least several times larger than the LLD so that measurements have sufficient precision to make valid decisions.

Sponsoring Organization:
USDOE
OSTI ID:
696827
Journal Information:
Health Physics, Vol. 77, Issue 5SUP; Other Information: PBD: Nov 1999
Country of Publication:
United States
Language:
English

Similar Records

Extension of Fong and Alvarez: When is a lower limit of detection low enough
Journal Article · Mon Nov 01 00:00:00 EST 1999 · Health Physics · OSTI ID:696827

When is a lower limit of detection low enough?
Journal Article · Sat Feb 01 00:00:00 EST 1997 · Health Physics · OSTI ID:696827

Confidence intervals for low-level, paired counting
Journal Article · Mon Nov 01 00:00:00 EST 1999 · Health Physics · OSTI ID:696827