Phase splitting of wet steam in annular flow through a horizontal impacting tee
Journal Article
·
· SPE Production Engineering (Society of Petroleum Engineers); (United States)
- E and P Technology Dept., Texaco Inc., Houston, TX (United States)
Phase splitting occurs during gas/liquid two-phase flow through pipe junctions and causes a gas/liquid mass ratio in the outlet legs of the junction that is different form that at the inlet. In steamflood distribution networks, this results in different steam qualities at the outlets of a junction than at the inlet. This, in turn, results in a heat distribution not in accordance with the mass distribution in the outlets of the tee. Because heat management of a steamflood project is important for both economic incentives and ultimate recovery, phase splitting must be understood and controlled. This paper presents the results of an experimental investigation conducted on phase splitting of wet steam during annular flow through a horizontal 2-in. impacting tee. The experimental operating range included inlet pressures of 400 and 600 psig, inlet mass fluxes form 1,180 to 10,150 lbm/(in[sup 2]-hr), inlet steam qualities form 0.2 to 0.8, and outlet vapor extraction ratios for one outlet leg from 0.2 to 0.5.
- OSTI ID:
- 6964718
- Journal Information:
- SPE Production Engineering (Society of Petroleum Engineers); (United States), Journal Name: SPE Production Engineering (Society of Petroleum Engineers); (United States) Vol. 7:4; ISSN SPENES; ISSN 0885-9221
- Country of Publication:
- United States
- Language:
- English
Similar Records
Phase splitting of wet stream in annular flow through a horizontal branching tee
Two-phase flow splitting at an impacting tee
Experimental investigation of steam-water annular flow in piping junctions
Journal Article
·
Wed May 01 00:00:00 EDT 1996
· SPE Production and Facilities
·
OSTI ID:227846
Two-phase flow splitting at an impacting tee
Journal Article
·
Tue Aug 01 00:00:00 EDT 1995
· SPE Production and Facilities
·
OSTI ID:87498
Experimental investigation of steam-water annular flow in piping junctions
Conference
·
Wed Dec 31 23:00:00 EST 1986
·
OSTI ID:6532142
Related Subjects
02 PETROLEUM
020300 -- Petroleum-- Drilling & Production
022000* -- Petroleum-- Transport
Handling
& Storage
42 ENGINEERING
420205 -- Engineering-- Transport & Storage Facilities-- (1980-)
420400 -- Engineering-- Heat Transfer & Fluid Flow
ENERGY TRANSFER
ENHANCED RECOVERY
FLUID FLOW
FLUID INJECTION
HEAT TRANSFER
MANAGEMENT
OIL WELLS
PIPELINES
STEAM INJECTION
TWO-PHASE FLOW
WELLS
020300 -- Petroleum-- Drilling & Production
022000* -- Petroleum-- Transport
Handling
& Storage
42 ENGINEERING
420205 -- Engineering-- Transport & Storage Facilities-- (1980-)
420400 -- Engineering-- Heat Transfer & Fluid Flow
ENERGY TRANSFER
ENHANCED RECOVERY
FLUID FLOW
FLUID INJECTION
HEAT TRANSFER
MANAGEMENT
OIL WELLS
PIPELINES
STEAM INJECTION
TWO-PHASE FLOW
WELLS