Revised Emergency Cooling System LOCA (loss-of-coolant accidents) limits for PKL-reactor Mark 16B-31 charges

Technical Report ·
OSTI ID:6961164
Recent experiments have shown that the assembly damage models used to compute generic Emergency Cooling System (ECS) limits for loss-of-coolant accidents (LOCA) in Mark 16B-31 charges may be nonconservative. The bases of these damage models were experiments that underestimated the heat input into a heated flow channel. This document provides interim ECS limits for Mark 16, Mark 31A, and Mark 31B assemblies. 2 refs., 1 tab.