A high charge state multicusp ion source

Conference · · Review of Scientific Instruments; (USA)
OSTI ID:6960523
;  [1]
  1. Accelerator and Fusion Research Division, Lawrence Berkeley Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (US)

Attempts have been made to generate high charge state ion beams by employing a multicusp plasma source. Three experimental investigations have been performed at Lawrence Berkeley Laboratory (LBL) and at Gesellschaft fuer Schwerionenforschung, Darmstadt (GSI) to study the charge state distributions and the emittance of the extracted beam. Results demonstrate that charge state as high as +7 can be obtained with argon or xenon plasmas. The brightness of a 11-mA xenon ion beam is found to be 26 A/({pi} mm mrad){sup 2}.