Fundamental attributes of a practical configuration management program for nuclear plant design control

Technical Report ·
OSTI ID:6957110
This summarizes the results of an evaluation of findings identifies during a number of Safety-System Functional Inspections and Safety System Outage Modification Inspections which are related to configuration management for nuclear plant design control. A computerized database of these findings was generated from a review of the design inspection reports. Based on the results of the evaluation, attributes of a configuration management program were developed which are responsive to minimizing these types of inspection findings. Incorporation of these key attributes is considered good practice in the development of a configuration management program for design control at operating nuclear plants.
Research Organization:
Nuclear Regulatory Commission, Washington, DC (USA). Div. of Licensee Performance and Quality Evaluation; ERC International, Plymouth Meeting, PA (USA). WESTEC Power Engineering Div.
OSTI ID:
6957110
Report Number(s):
NUREG/CR-5147; ON: TI88012821
Country of Publication:
United States
Language:
English