Laboratory and field evaluation of the Semi-VOST (semi-volatile organic sampling train) method

Technical Report ·
OSTI ID:6943928

Laboratory studies and a second field evaluation have been completed to assess the performance of the Semi-Volatile Organic Sampling Train (Semi-VOST) method for measuring concentrations of principal organic hazardous constituents (POHCs) with boiling points greater than 100/sup 0/C emitted from hazardous-waste incineration. The Semi-VOST methodology was tested initially through a series of laboratory experiments and a field test at a hazardous waste incinerator. In the first field-test method precision and bias were shown to be compound specific. The second field test was performed at a hazardous-waste incinerator using five gaseous deuterated compounds to dynamically spike four simultaneously operating Semi-VOST trains. Toluene, 1,1,2,2-tetrachloroethane, and chlorobenzene were chosen because of boiling point and chemical functionality.

Research Organization:
Radian Corp., Research Triangle Park, NC (USA)