Dust and ventilation effects on radiant barriers: Cooling season energy measurements
- Oak Ridge National Lab., TN (USA)
- Tennessee Valley Authority, Knoxville, TN (USA)
Cooling season tests were conducted in three unoccupied ranch-style houses in Karns, Tennessee, to determine the effects on attic radiant barrier performance incurred by changes in attic ventilation area ratio, attic ventilation type, and the buildup of dust on horizontal radiant barriers. All three houses had R-19 fiberglass batt insulation in their attics. Horizontal radiant barriers were artificially dusted and the dusted barriers showed measurable performance degradations, although the dusted barriers were still superior to no radiant barriers. Dust loadings of 0.34 and 0.74 mg/cm{sup 2} reduced a clean radiant barrier surface emissivity of 0.055 to 0.125 and 0.185, respectively. Total house cooling load increases amounted to 2.3 and 8.4% compared to house loads with clean horizontal barriers, respectively. When compared to R-19 with no horizontal radiant barrier conditions, the dusted horizontal radiant barriers reduced cooling loads by about 7%. Testing showed that increasing the attic ventilation area ratio from the minimum recommended of 1/300 to 1/150 had little if any effect on the house cooling load with either truss or horizontal barriers present in the attics. Radiant barriers, however, still reduced the house cooling load. There was essentially no difference in house cooling load reduction between either ridge/soffit or gable/soffit vent type with a truss radiant barrier, as both reduced cooling loads by about 8% when compared to no radiant barrier conditions. The attic-ventilation-type testing was done with a ventilation area ratio of 1/150.
- Research Organization:
- Electric Power Research Inst., Palo Alto, CA (USA); Oak Ridge National Lab., TN (USA)
- Sponsoring Organization:
- DOE/CE; EPRI; TVA
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 6927326
- Report Number(s):
- EPRI-CU-6817
- Country of Publication:
- United States
- Language:
- English
Similar Records
Cooling season energy measurements of dust and ventilation effects on radiant barriers
Cooling energy measurements of single-family houses with attics containing radiant barriers in combination with R-11 and R-30 ceiling insulation
Related Subjects
320107* -- Energy Conservation
Consumption
& Utilization-- Building Systems-- (1987-)
ATTICS
BUILDINGS
ENERGY TRANSFER
FIBERGLASS
FIELD TESTS
HEAT TRANSFER
PERFORMANCE
RESIDENTIAL BUILDINGS
TESTING
THERMAL BARRIERS
THERMAL INSULATION
VENTILATION